9
10mm
55mm
EARTH
LIVE
NEUTRAL
FIT EARTHING SLEEVE
Diagram 7
IMPORTANT Connect flying lead from PCB
to rear of the front cover - see
Replace the front cover and fasten in position
with four screws.
Diagram 6.
Changing The Operating Mode
Templock/Normal
On the extreme right hand side of the PCB
mid way up is the ‘4 Way Temp Limit Slider
Switch’ (See Diagram 8).
PLEASE NOTE! The Selectronic Premier is
factory set with the ‘Temp Limit Slider Switch’
set at ‘Locked Position 1’.
After the unit is commissioned, you have the
option of choosing from any of three different
lockable temperature settings plus normal
operation position from left to right.
Remove the front cover taking care not to strain
the flying lead.
Change the switch to the desired temperature
control position.
WARNING! Switch OFF the electricity
at the isolating switch before removing
the cover.
Replace and refasten the front cover.
Switch on electricity. Check that the unit operates correctly.
PLEASE NOTE! The Temperature Lock light on the front cover of the shower will not illuminate if
Normal Position 4 has been selected.
Locked Position 1
(Extreme Left)
Locked Position 2
(First ‘Click’ from
the Extreme Left)
Locked Position 3
(Second ‘Click’ from
the Extreme Left)
Unlocked Position 4
(Extreme Right)
Temperature
Adjustment Range
34-40 C Nominal°
34-41 C Nominal°
34-43 C Nominal° 25-46 C Nominal°
Diagram 8
LOCKED
POSITION
’1’
LOCKED
POSITION
’2’
LOCKED
POSITION
’3’
UNLOCKED
POSITION
’4’
Changing ‘DIP Switch’ Default Setting
On the PCB directly to the left of the transformer there are two sets of vertically arranged ‘DIP
Switches’ (See Diagram 9) The top set of 3 are NOT TO BE CHANGED they are used for the shower
software configuration.
WARNING! Switch OFF the electricity at the isolating switch before removing the cover.
16
5. A stabiliser is built into the flow
valve to automatically compensate
for small fluctuations in water
pressure that frequently occur in
households.
There are three further controls to
cater for exceptional reductions in
water pressure to prevent the
shower from getting too hot.
a) If the flow of water is less than
1.0 l/min the power to the
elements is switched off, but the
solenoid valve remains open
allowing water to flow through
the shower.
b) If the outlet temperature sensor
senses an excessive
temperature the flow of water
and the heating elements will
automatically switch off. The
electronics will signal over
Temperature condition (see
“over temperature shutdown”
section).
c) A two stage mechanical thermal
cut-out is mounted on the top of
the heat exchanger independent
of the electronics.
Stage one switches the power
off to the elements if it senses
an excessive temperature.
The switch operates with an
audible click and will reset if
cold water is run through the
shower.
Stage two only operates if an
extreme temperature is sensed.
The cut out will permanently
switch off and it will then have
to be replaced.
6. A pressure relief device is fitted to
safeguard against abnormal
pressure conditions, and provides
a level of appliance protection
should an excessive build of
pressure occur within the shower.
If this operates a replacement part
will be required.
E
N
S
URE
POW
E
R
I
S
OF
F
B
E
F
O
RE REM
OV
I
NG C
O
VE
R.
R
EP
L
A
C
E
T
HIS
C
O
VER
P
R
I
OR T
O F
RF
I
T
T
I
NG
T
HE
F
RONT
COVE
R
.
W
AR
N
I
NG
WARNING
THIS
PRODUCT
MUST BE
EARTHED
TERMINAL
BLOCK
TEMPLOCK
SWITCH
SOLENOID
VALVE
INLET
COVER
POWER
PCB
BRASS
COOLER
MOTOR
FLOW
TRANSDUCER
FLOW
VALVE
OUTLET
TEMP
SENSOR
PRESSURE
RELIEF
VALVE
OUTLET
HEAT
EXCHANGER
LOGIC
PCB
DIP
SWITCH
THERMAL
CUTOUT